AS-Interface Master - Modbus RTU Slave

Anybus X-gateway allows you to realize a seamless internal connection between AS-Interface and Modbus networks for PLC control systems and their connected devices.

Fast copying of I/O data

The main function of the X-gateway is the fast transfer of cyclic I/O data between two networks. This allows your PLC to do no additional calculation work. The gateway acts as master on the AS-Interface network and as slave on the Modbus network. The data transfer is completely transparent and has a maximum data capacity of 512 bytes in each direction.

Simple to formulate - no programming required!

The connection between the two networks is quickly established in the Anybus Configuratuion Manager software included with the X-gateway. no programming skills are required to set up the X-gateway. By factory default, the X-gateway has a predefined I/O size of 20 bytes.

Data Sheet Download

描述

Features and Benefits

  • Fast recovery of cyclic I/O data between two networks (10-15 ms)
  • Validated and tested by all PLC manufacturers
  • Supports up to 512 bytes of input and output data in each direction.
  • Powerful master interface for AS-Interface, no PLC controller required
  • Optional control and status messages can be added to I/O data for diagnostic purposes.
  • Rugged, self-contained housing for use in harsh industrial environments
  • Free worldwide technical support and consultation

AS-Interface master interface

When an off-the-shelf AS-Interface control PLC is not available, the Anybus X-gateway with integrated AS-Interface M4 master interface can be used.

  • Compliant with AS-Interface 3.0 specification
  • Controls up to 62 AS-Interface slaves.
  • Optional online device list showing the active status of connected slaves
  • Support for Combined Transaction Types 1, 2, 3, 4, 51
  • Up to 248 digital inputs and 186 digital outputs
  • Up to 124 (16-bit) analog values
  • AS-Interface baud rate 167 kbit/s
  • Synchronized I/O (optional)
  • On-Board Configuration Buttons
  • 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration
  • 2x 2-pin 5,08 Phoenix plug connection

 

Modbus RTU slave interface

Modbus RTU network address setting can be realized by configuring the switch on board.

  • Full Modbus RTU slave functionality
  • Maximum 512 bytes of input data and 512 bytes of output data
  • Modbus Diagnostic Support
  • Configuration via on-board DIP switch
  • Modbus RTU baud rate 12-57,6 kbit/s
  • 1x D-sub 9-pin female network connector

 

Technical Specifications

Dimensions (L-W-H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00″
Weight 400g or 0,880 lbs
Operating temperature -25 to +65 °C or -13 to +149 °F
Storage temperature -40 to +85 °C or -40 to +185 °F
Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption     max. 400mA (Typical 200mA)
Enclosure material  Aluminium and plastic
Installation position Vertical / Flat*
Galvanic isolation YES, on both BUS/Ethernet side
Mechanical rating IP20, NEMA rating 1
Mounting DIN-rail (EN 50022 standard)
I/O configuration via USB port with Anybus Configuration Manager software
Certifications CE., CULUSRoHS

 

Ordering Information

Order Code AB7828
         Deliverables Gateway
Quick Start Documentation USB Configuration Cable
Includes power supply
Configuration software available for download

 