AS-Interface Master - Modbus RTU Slave
Anybus X-gateway allows you to realize a seamless internal connection between AS-Interface and Modbus networks for PLC control systems and their connected devices.
Fast copying of I/O data
The main function of the X-gateway is the fast transfer of cyclic I/O data between two networks. This allows your PLC to do no additional calculation work. The gateway acts as master on the AS-Interface network and as slave on the Modbus network. The data transfer is completely transparent and has a maximum data capacity of 512 bytes in each direction.
Simple to formulate - no programming required!
The connection between the two networks is quickly established in the Anybus Configuratuion Manager software included with the X-gateway. no programming skills are required to set up the X-gateway. By factory default, the X-gateway has a predefined I/O size of 20 bytes.
Description
Features and Benefits
- Fast recovery of cyclic I/O data between two networks (10-15 ms)
- Validated and tested by all PLC manufacturers
- Supports up to 512 bytes of input and output data in each direction.
- Powerful master interface for AS-Interface, no PLC controller required
- Optional control and status messages can be added to I/O data for diagnostic purposes.
- Rugged, self-contained housing for use in harsh industrial environments
- Free worldwide technical support and consultation
AS-Interface master interface
When an off-the-shelf AS-Interface control PLC is not available, the Anybus X-gateway with integrated AS-Interface M4 master interface can be used.
- Compliant with AS-Interface 3.0 specification
- Controls up to 62 AS-Interface slaves.
- Optional online device list showing the active status of connected slaves
- Support for Combined Transaction Types 1, 2, 3, 4, 51
- Up to 248 digital inputs and 186 digital outputs
- Up to 124 (16-bit) analog values
- AS-Interface baud rate 167 kbit/s
- Synchronized I/O (optional)
- On-Board Configuration Buttons
- 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration
- 2x 2-pin 5,08 Phoenix plug connection
Modbus RTU slave interface
Modbus RTU network address setting can be realized by configuring the switch on board.
- Full Modbus RTU slave functionality
- Maximum 512 bytes of input data and 512 bytes of output data
- Modbus Diagnostic Support
- Configuration via on-board DIP switch
- Modbus RTU baud rate 12-57,6 kbit/s
- 1x D-sub 9-pin female network connector
Technical Specifications
| Dimensions (L-W-H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00″ |
| Weight | 400g or 0,880 lbs |
| Operating temperature | -25 to +65 °C or -13 to +149 °F |
| Storage temperature | -40 to +85 °C or -40 to +185 °F |
| Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
| Current consumption | max. 400mA (Typical 200mA) |
| Enclosure material | Aluminium and plastic |
| Installation position | Vertical / Flat* |
| Galvanic isolation | YES, on both BUS/Ethernet side |
| Mechanical rating | IP20, NEMA rating 1 |
| Mounting | DIN-rail (EN 50022 standard) |
| I/O configuration | via USB port with Anybus Configuration Manager software |
| Certifications | CE., CULUS, RoHS |
Ordering Information
| Order Code | AB7828 |
|---|---|
| Deliverables | Gateway Quick Start Documentation USB Configuration Cable 不 Includes power supply Configuration software available for download |
Warranty: 3 years. For purchase instructions and terms and conditions, please contactsupport@hongtronics.com