AS-Interface Master - Modbus RTU Slave

Anybus X-gateway allows you to realize a seamless internal connection between AS-Interface and Modbus networks for PLC control systems and their connected devices.

Fast copying of I/O data

The main function of the X-gateway is the fast transfer of cyclic I/O data between two networks. This allows your PLC to do no additional calculation work. The gateway acts as master on the AS-Interface network and as slave on the Modbus network. The data transfer is completely transparent and has a maximum data capacity of 512 bytes in each direction.

Simple to formulate - no programming required!

The connection between the two networks is quickly established in the Anybus Configuratuion Manager software included with the X-gateway. no programming skills are required to set up the X-gateway. By factory default, the X-gateway has a predefined I/O size of 20 bytes.

Data Sheet Download

Description

Features and Benefits

  • Fast recovery of cyclic I/O data between two networks (10-15 ms)
  • Validated and tested by all PLC manufacturers
  • Supports up to 512 bytes of input and output data in each direction.
  • Powerful master interface for AS-Interface, no PLC controller required
  • Optional control and status messages can be added to I/O data for diagnostic purposes.
  • Rugged, self-contained housing for use in harsh industrial environments
  • Free worldwide technical support and consultation

AS-Interface master interface

When an off-the-shelf AS-Interface control PLC is not available, the Anybus X-gateway with integrated AS-Interface M4 master interface can be used.

  • Compliant with AS-Interface 3.0 specification
  • Controls up to 62 AS-Interface slaves.
  • Optional online device list showing the active status of connected slaves
  • Support for Combined Transaction Types 1, 2, 3, 4, 51
  • Up to 248 digital inputs and 186 digital outputs
  • Up to 124 (16-bit) analog values
  • AS-Interface baud rate 167 kbit/s
  • Synchronized I/O (optional)
  • On-Board Configuration Buttons
  • 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration
  • 2x 2-pin 5,08 Phoenix plug connection

 

Modbus RTU slave interface

Modbus RTU network address setting can be realized by configuring the switch on board.

  • Full Modbus RTU slave functionality
  • Maximum 512 bytes of input data and 512 bytes of output data
  • Modbus Diagnostic Support
  • Configuration via on-board DIP switch
  • Modbus RTU baud rate 12-57,6 kbit/s
  • 1x D-sub 9-pin female network connector

 

Technical Specifications

Dimensions (L-W-H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00″
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C or -13 to +149 °F
Storage temperature-40 to +85 °C or -40 to +185 °F
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE., CULUSRoHS

 

Ordering Information

Order CodeAB7828
         DeliverablesGateway
Quick Start Documentation USB Configuration Cable
Includes power supply
Configuration software available for download

 

Warranty: 3 years. For purchase instructions and terms and conditions, please contactsupport@hongtronics.com