CAN-CR120/HV
Function Overview.
The Ixxat CAN-CR120/HV repeater is a 3 kV current isolated CAN/CAN FD repeater with two CAN/CAN FD interfaces that provides up to 3 kV current isolation for enhanced protection of the network segments. It increases the load capacity of the CAN bus, establishes the physical coupling of the bus system, and provides the flexibility to optimize the network structure.
Description
Products
Features and Benefits:
- Designed for industrial environments, they meet high requirements for ruggedness, temperature range and safety for demanding applications.
- Provides flexible CAN FD network design with support for short cutoffs, star and tree topologies to optimize CAN/CAN FD network architecture.
- Fast and transparent operation, realizing line lengths of approximately 35 meters (175 ns delay), compatibility with all high-level protocols, and minimal impact on real-time behavior.
- Simplified cabling design reduces the number of cables, lowers installation and maintenance costs, and improves efficiency.
- Enhances network reliability by providing electrical isolation up to 3 kV DC (for 1 second) to protect equipment from voltage spikes.
- Automatic network monitoring and fault recovery, disconnecting affected network segments and restoring them automatically after the fault is removed.
Deliverables: CAN Repeater, User's Manual
- Net width: 99 mm
- Net height: 113 mm
- Net depth: 22.6 mm
- Net weight: 180 grams
Power & Current
- Current consumption type: 70 mA
- Maximum current consumption at rated Vcc: 100 mA
- Input Voltage: +9V to +36V DC
- Isolation: 3 kV DC 1 sec.
Operating Temperature Range
- Minimum operating temperature: -20°C
- Maximum operating temperature: 70°C
- Storage temperature range: -40°C to 85°C
- Relative humidity: 10 to 95 %, non-condensing
makings
- Housing material: Polyamide housing for top hat rail mounting
- Packaging material: cardboard
- Warranty period (years): 1 year
- CE certification: Yes
- U.S. FCC Certification: Yes
- Waste Electrical and Electronic Equipment (WEEE) Category: IT and Telecommunications Equipment
- Protection level IP: IP20
- cULus Certification: yes
- Connectors: 2 screw terminals, 1 power connector
- Pool included: No
CAN Mode: CAN High Speed with CAN Choke (ISO 11898-2)
- CAN Transceiver: TI SN65HVD251
- CAN baud rate: up to 1 Mbit/s
- CAN FD mode: ISO CAN FD, non-ISO CAN FD
- CAN FD baud rate: arbitration rate up to 1000 kBit/s, data rate up to 8000 kBit/s (tested and proven). User definable bit rate.
- CAN FD Transceiver: MCP2562FD