MSR255 Data Logger: robust and versatile with LCD display
Up to 5 different sensors, 4 additional analog inputs and an easy-to-read LCD display are integrated in the compact MSR255 for maximum flexibility and user-friendliness.
5 Sensors, 4 Analog Inputs
The MSR255 can be configured for different measurement tasks: temperature, humidity, air pressure and light sensors (for inside the case or outside the cable) can be selected, together with the same sensor for measuring triaxial acceleration.Acceleration values are measured at up to 3200 Hz and saved at a rate of approx. 50 Hz via digital filtering.In addition, the voltages of four external analog channels or sensors can be recorded.The analog input has an alarm output, multiple outputs for switching power and an input for starting and stopping data logging.
The MSR255 has a memory capacity of more than 2 000 000 measurement parameters.The high capacity lithium polymer battery makes it ideal for long term data acquisition applications.The 4-line backlit LCD has four individually configurable views.The 4-line backlit LCD display has 4 independently configurable view menus.All collected data can be quickly downloaded to a computer or notebook via the USB port.
Optional: 0.... .14 bar absolute pressure -20... +65 °C
±50 mbar (1.... .10 bar absolute pressure, +25 °C)
P2
3-axis acceleration
±15 g
±0.15 g (+25 °C)
Acceleration: 50 / S (3200 / s) Status: 1 / s to 1/12h
A
sunlight
0.... .65 000 lx
Most sensitive at 500nm
1 / s to 1/12 h
L
3. Do you need an external sensor instead of a built-in sensor?
In addition to the internal temperature, humidity, air pressure, 3-axis acceleration sensors and optical sensors, you can select the appropriate external sensors (non-pluggable) for the MSR255 DataCORDER.
External Sensor
Measurement Range
Cable Length
0.15 m
0.40 m
1.00 m
1.60 m
Temperature
-55... +125 °C
CodingFT2/015
CodingFT2/040
CodingFT2/100
CodingFT2/160
Humidity
0... .100 %rH
CodingFH/015
CodingFH/040
CodingFH/100
CodingFH/160
Air Pressure
2.0 bar
CodingFP/015
CodingFP/040
CodingFP/100
CodingFP/160
14 bar
CodingFP2/015
CodingFP2/040
CodingFP2/100
CodingFP2/160
3-axis acceleration
±15 g
CodingFA/015
CodingFA/040
CodingFA/100
CodingFA/160
sunlight
0.... .65 000 lx
CodingFL/015
CodingFL/040
CodingFL/100
CodingFL/160
4. Do you need 4 analog inputs to connect a third-party sensor?
You can extend the application range of the MSR225 data logger with four analog-specific inputs.These increased inputs can be used to measure more sensors in the task.These third-party sensors can also be powered by the Logger's internal battery, if desired.The ECORDER's power can also be turned on automatically at a pre-set time.This design takes into account the fact that those sensors that need to be warmed up will have an adequate warm-up period.
Simulation Input
Input
Input Configuration
Coding
Includes an alarm output, multi-output switching power supply and an output This is used to start and stop data logging.
Measurement/storage rate: 1 / s to 1/12h
4 analog inputs
(Resolution: 12 bits)
0.... .3.0 V - Standard
E3333
4 analog inputs
(Resolution: 12 bits)
Select the corresponding input configuration:
( 1 )0.... .20 mA ( 2 )4.... .20 mA ( 3 )0... .3.0 V ( 4 )0.5... .4.5 V / 0... .5.0 V ( 5 )0... .10.0 V / 1.0.... .6.0 V ( 6 )0... .12.0 V ( 7 )0... .24.0 V
Exxxx
5. our prices and delivery terms!
Request a quote by filling out the form
The code above shows the type of recorder and sensor you have selected.For a quote, please let us know by filling out the form below!