MPL2510 Series DPSS Ultra-Compact Passive Q Sub-Picosecond Pulse Lasers

在100 Hz重複頻率下提供高峰值功率> 4 MW。短鐳射腔固定在熱穩定和可控的底板上,使輸出參數性能極其穩定,佔用空間小,更適合OEM集成。亞皮秒脈衝持續時間< 500 ps,高脈衝能量超過2 mJ和可變重複率從1 Hz到100 Hz。

Description

Product Description

MPL2510系列DPSS被動調Q亞皮秒雷射器在100 Hz重複頻率下提供高峰值功率> 4 MW。短鐳射腔固定在熱穩定和可控的底板上,使輸出參數性能極其穩定。佔用空間小更適合OEM整合。亞皮秒脈衝持續時間< 500 ps,高脈衝能量超過2 mJ和可變重複率從1 Hz到100 Hz。

MPL2510系列DPSS被動調Q亞皮秒雷射器涵蓋了許多應用,如污染監測,DNA分析,超連續譜生成等。由於脈衝持續時間短,脈衝能量高,鐳射可提供高達4 MW的峰值功率。支持多波長選擇:綠色(532 nm)和紫外線(355 nm, 266 nm)。

Advantages and Features

  • 2mJ pulse energy at 1064 nm
  • Short pulse duration<500 ps
  • 1 ~ 100 HzThe repetition frequency of
  • Ultra-compact, passive tuningQ
  • Average power: 200 mW
  • Peak power:4 MW
  • Guarantee >3 Gshot Life
  • Other Wavelength Customization(532 nm, 355 nm, 266 nm)
優勢與特點

Applications

Laser Induced Breakdown Spectroscopy (LIBS)

LIBS:Using laser pulse to penetrate the sample material and generate plasma.This is a technique for determining the chemical elemental composition of a sample by analyzing the spectral information in plasma.

The LIBS Advantage:

  • No sample preparation required
  • Non-Contact
  • Multi-element analysis
  • immediacy
激光誘導擊穿光譜

Laser Surface Cleaning

Realization of laser surface cleaning:

The heat generated by the laser beam loosens, breaks up, evaporates or strips away contaminants.

Advantage:

  • Non-Contact
  • highly accurate
  • high efficiency
  • controllability
  • Environmentally Friendly

Laser Scar Revision

Repair method:

  • Photothermal effect: Laser light breaks down scar tissue and promotes new collagen production.
  • Photochemical effects: changes in chemical structure and pigmentation
  • Stimulates cell growth: stimulates cell growth and regeneration in the skin

Why Laser Scar Revision?

  • non-invasive
  • Accuracy
  • Adjustability
疤痕修復
時間分辨

Time-Resolved Fluorescence Detection

Time-Resolved Fluorescence Detection: To study the fluorescence properties of molecules, compounds or samples and to measure the characteristics of fluorescence emission in a time-resolved manner, the MNL1342 provides short pulse duration, high pulse energy and high repetition frequency for laser scar revision.

Excitation - Emission - Time Measurement

Advantage:

  • high resolution
  • Fluorescent Life Measurement
  • high sensitivity
  • optical resolution
  • No marking required

Other Applications

  • DNA analysis
  • Pollution Monitoring
  • remoteness
  • Hypercontinuous Spectrum Generation
  • Mixed Gas Ignition
其他應用

Size

1. All specification parameters are subject to change due to continuous optimization. All parameters are measured at 1064 wavelengths unless otherwise specified.

2. FWHM measured at 1064 wavelengths. Other pulse widths available

3. Average measurement interval 60s

4. 8 hours of testing, the longest warm-up 5 minutes, the external temperature change is less than ± 2 ℃.

5. The factory default setting is maximum repetition rate.

6. Full angle measurement at 1/e² position

7. RMS value measured at 1000 frames per second for 5 sequences of photography

8. Velocity of light measured at 1/e² in diameter, 20 cm from the laser output.

9. Finger modulation Q triggers a rising pulse.

10. The laser can be adapted to a 12 VDC power supply.