ECOLOG TH1(800440)
ECOLOG TH1(800440)
- Temperature/Humidity Data Logger
- High Accuracy Instruments ±1.5 %RH, ±0.2 °C
- Reliable and recognized data logger
| Product Category | Data Logger |
| Software Type | Logger, Non-Internet |
| Probe Type | Combination Probe T/RH, External |
| Typical Application Areas | Freezer, refrigerator, room, climate room. |
| Measurement parameters | Temperature/Humidity |
| Measurement Range Temperature | -35°C ... + 55°C |
| Measurement Range Humidity | 0% relative humidity. .100% relative humidity |
| Measurement Range Accuracy Temperature | ±0.2°C [+0.1°C ... + 30.0°C] / ±0.3°C [-24.9°C ... ±0.0°C; +30.1°C ... + 70.0°C] /±0.4°C [-50.0°C ... - 25.0°C; +70.1°C ... + 100.0°C] /±0.7°C [+100.1°C ... + 140.0°C] |
| Measurement Accuracy Humidity | Relative humidity: ±1.5% [+23°C]. |
| usage | multiple use |
| Alarms | Alarm Threshold |
| Connectivity | DB 15 |
| Life expectancy | 10 years |
| Memory Capacity | 64’000 measurements per logger |
| sizes | 110 x 35 x 85 mm (4.3 x 1.4 x 3.4) |
| makings | ABS plastic |
| certificate | Certificates |
Description
summarize
- 2-channel temperature/humidity recorder without T/RH sensor
- Measurement range: -35°C ... + 55°C and 0...100% RH
- Storage capacity: 32’000 values per channel
- Connection: RS232, 2-digit word input
- Alarm Output
- Validation certificate (validation points -0.4, + 73.3°C and 5% RH, 88.4% RH at 23°C).
Technical Specifications
| Product Category | Data Logger |
| Software Type | Logger, Non-Internet |
| Probe Type | Combination Probe T/RH, External |
| Typical Application Areas | Freezer, refrigerator, room, climate room. |
| Measurement parameters | Temperature/Humidity |
| Measurement Range Temperature | -35°C ... + 55°C |
| Measurement Range Humidity | 0% relative humidity. .100% relative humidity |
| Measurement Range Accuracy Temperature | ±0.2°C [+0.1°C ... + 30.0°C] / ±0.3°C [-24.9°C ... ±0.0°C; +30.1°C ... + 70.0°C] /±0.4°C [-50.0°C ... - 25.0°C; +70.1°C ... + 100.0°C] /±0.7°C [+100.1°C ... + 140.0°C] |
| Measurement Accuracy Humidity | Relative humidity: ±1.5% [+23°C]. |
| usage | multiple use |
| Alarms | Alarm Threshold |
| Connectivity | DB 15 |
| Life expectancy | 10 years |
| Memory Capacity | 64’000 measurements per logger |
| sizes | 110 x 35 x 85 mm (4.3 x 1.4 x 3.4) |
| makings | ABS plastic |
| certificate | Certificates |
Document Information
replacement (parts)

Software for configuring ECOLOG Data Logger for Windows XP, Vista, 7, 8, 10, Server 2003, 2008, 2012 and performing detailed data analysis. Full version* 3.64.01 *