ecolog-pro 2ptr 915 (801428)

The ECOLOG-PRO 2PTR is a measurement module with two external temperature sensors. Communication between the module and the ECOLOG-PRO RBR is via radio signals.

Power Supply3 AA alkaline batteries
Battery Life14 months (provided the module's radio connection is stable and the
Maintain the defined temperature range (see below)
Probe TypeExternal 4-wire Pt100 probe
Probe ConnectionStandard probe: Pt100 temperature sensor, 3m cable, unshielded
Expansion: up to 17 meters, unshielded
Measurement Range-200 °C... +200 °C
Measurement accuracy±0.2
Measurement Resolution0.1 °C
Logging and Communication Interval1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software (ELPRO)
(cloud) Note: The recording interval will affect the battery life.
conduit2 independent temperature channels with individually connected sensors
Memory Capacity43’000 measurements
Ambient Storage Temperature/Humidity-10 °C... +50 °C
10 %RH...90 %RH, non-condensing
Ambient Operating Temperature/Humidity0°C ... + 40°C
10%RH...90%RH, no condensation
Working altitudeDo not use this equipment class at altitudes above 2000 meters above sea level
ID number“ Q ” followed by a 6-digit character; ID number used to identify the module
ELPRO Cloud software.
Radio to Communication ModuleAvailable in two versions: 868 MHz (Europe) or 915 MHz (US)
Note: Only the included antenna can be used.

Description

summarize

Radio measurement module for two external Pt100 temperature sensors;915 MHz (US).The module communicates with the ECOLOG-PRO RBR via radio signals.Does not include probes.

 

Technical Specifications

Power Supply3 AA alkaline batteries
Battery Life14 months (provided the module's radio connection is stable and the
Maintain the defined temperature range (see below)
Probe TypeExternal 4-wire Pt100 probe
Probe ConnectionStandard probe: Pt100 temperature sensor, 3m cable, unshielded
Expansion: up to 17 meters, unshielded
Measurement Range-200 °C... +200 °C
Measurement accuracy±0.2
Measurement Resolution0.1 °C
Logging and Communication Interval1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software (ELPRO)
(cloud) Note: The recording interval will affect the battery life.
conduit2 independent temperature channels with individually connected sensors
Memory Capacity43’000 measurements
Ambient Storage Temperature/Humidity-10 °C... +50 °C
10 %RH...90 %RH, non-condensing
Ambient Operating Temperature/Humidity0°C ... + 40°C
10%RH...90%RH, no condensation
Working altitudeDo not use this equipment class at altitudes above 2000 meters above sea level
ID number“ Q ” followed by a 6-digit character; ID number used to identify the module
ELPRO Cloud software.
Radio to Communication ModuleAvailable in two versions: 868 MHz (Europe) or 915 MHz (US)