Anybus Communicator - Modbus TCP
Integration of RS-232/422/485 based serial industrial equipment and devices into MODBUS TCP control system without any changes to the devices. Simply connect and configure!
Anybus Communicator is a proven and reliable protocol converter gateway that connects non-connected industrial equipment and devices to MODBUS TCP. The gateway performs intelligent protocol conversion and presents serial data as easy to process I/O data to the host PLC/controller.
The Communicator is a slim standalone gateway designed for IP20 and DIN rail mounting and requires 24 Volt power.The Communicator has been conformance tested to the current MODBUS TCP specification to ensure network compatibility.
Convert almost any type of serial protocols
Communicator is capable of converting almost any type of serial protocol, such as Modbus RTU, ASCII, DF1 or any other type of proprietary query/response or production/consumption protocol.
Typical Serial Applications
Typical serial applications include inverter drives, sensors, actuators, human-machine interfaces, barcode readers, RFID readers and industrial scales.
Description
I. Features and Benefits
- Convert virtually any RS-232/422/485 request/response or production/consumer protocol - e.g. Modbus RTU, ASCII, DF1 - in minutes.
- Pre-defined for Modbus RTU. Avoid the hassle of writing scripts and building serial Modbus frameworks with the 6-step Modbus RTU wizard.
- No hardware or software changes required for connected automation equipment
- PLC compatible with leading manufacturers such as Siemens, Rockwell, Schneider Electric, etc.
- Protocol switching is done by a manual operator, no PLC function block is required.
- Convenient save/load functionality means that completed configurations can be reused for many other installations.
- Includes “Anybus Configuration Manager” with flexible serial frame building capabilities.”
- Versions with dual-port switched Ethernet allow daisy-chaining and eliminate the need for external switches.
- Free worldwide technical support and consultation
II. Serial Protocol Configuration Features
No advanced programming skills are required to set up Anybus® Communicator, as configuration is accomplished using the included, easy-to-use, Windows™-based ACM (Anybus Configuration Manager).
- Optional RS-232/422/485 interface
- Predefined 6-step Modbus-RTU configuration wizard
- Optional preloading of DF1 commands without script or serial frame creation
- Ability to configure ASCII or user-defined protocols (request/response or producer/consumer protocols via visual frame creation interface)
- Multi-language support: English, German, Spanish, Italian, French, Polish, Russian, Chinese and Japanese.
- Simple store/load functionality supports complete configurations that can be reused in many other installations
- Password protection prevents unauthorized configuration uploads and downloads
- Serial cable monitoring and built-in calibration calculations for diagnostics and troubleshooting.
MODBUS TCP function
MODBUS TCP Interface Features
- Modbus TCP class 0, class 1 and some class 2 device/slave functions
- Maximum 512 bytes input and 512 bytes I/O data
- 10/100Mbit running full or half duplex
- Also features dual RJ-45 ports with integrated switch for daisy chain topology
- Configuration of TCP/IP settings through web pages, configuration tools, DHCP or ARP.
Technical Specifications
Communicator RS-232/422/485
| Agreement | Configurable RS-232/422/485-based production/consumption, query/response ASCII |
| Maximum number of stations | 31 (with RS485/422) |
| baud | 1,2-57,6 kbit/s |
| Physical Standards | RS232/422/485 |
| Modbus commands | 0x11 Report Slave ID, 0x14 Read File Record, 0x15 Write File Record, 0x16 Mask Write Register, 0x17 Read/Write Multiple Registers, 0x18 Read FIFO Queue Customized commands can be created (in the Anybus Configuration Manager) |
| DF1 Service | 0x01 Integrity check, 0x02 Read diagnostics, 0x03 Read data, 0x04 Write data Customized services can be created (in Anybus Configuration Manager) Technical Details Standard |
Technical Details
| Dimensions (L x W x H) with Serial and Power Connectors | 120 x 75 x 27 mm 4,72 x 2,95 x 1,06” | |
| weights | 150 grams, 0.33 pounds | |
| Protection Level | IP20 Nema Grade 1 | |
| Shell Material | l PC ABS, UL 94 | |
| Mounting Position | whichever | |
| Installation | DIN rail (35 * 7,5/15) | EN50022 |
Certificates
| UL | File No.: E203225 | UL 508 Industrial Continued. Equation |
| Dangerous places | Category 1, part 2, groups A, B, C and D, T4 | ISA 12.12.01 |
| CE | 2004/108/EC | EN 61000-6-4 EN 61000-6-2 |
Electrical Characteristics
| Power supply | 24 VDC +/- 10 % |
| power wastage | 300 mA maximum, 100 mA typical |
Environmental Characteristics
| Reverse Voltage Protection | yea | |
| Short Circuit Protection | yea | |
| Subnet side current isolation | yea | EN 60950-1 |
| MTTF | >550 000 hours | Telcordia Issue 2, Method 1 Case 3 at 30 o C |
Hardware Characteristics
| Working Temperature | 0 to 55 degrees Celsius, 32 to 131 degrees Fahrenheit |
| Storage Temperature | -40 to 85 degrees Celsius, -40 to 185 degrees Fahrenheit |
| Relative Humidity | 0-95% Non-condensing |
| Mounting Height | Up to 2 000 m |
Industrial Environmental Resistance and Radiation Resistance
| Electrostatic discharge | +/- 4 kV | EN 61000-4-2 |
| High Frequency Electromagnetic Field | 10 V/m 80 MHz - 1 GHz 3 V/m 1,4 GHz - 2,0 GHz 1 V/m 2,0 GHz - 2,7 GHz | EN 61000-4-3 |
| Fast Transients | +/- 1 kV | EN 61000-4-4 |
| Surge Protection | +/- 1 kV | EN 61000-4-5 |
| RF interference | 10 Volt/RMS | EN 61000-4-6 |
| Radiation (10m distance) | 40 dB 30 MHz - 230 MHz 47 dB 30 MHz - 1 GHz | CISPR 16-2-3 |
Delivery contents
- Configure Cable (RS232) Port
- Installation Sheet
- Dsub with screw terminals for subnets
VII. Ordering information
Order Code: AB7028
Contained components:
- Quick Start Documentation
- Configuration cable (RS-232) shipped with each individual Communicator
-Each individual Communicator is shipped with a D-sub connector with screw terminals for serial subnets.
- Downloadable Configuration Software
- (excluding power supply)
Optional accessories are available:
- USB-RS-232 Configuration Adapter (Order Code: 019570)
Guarantee: 3 year warranty. For purchase instructions and terms and conditions, please contactsupport@hongtronics.com